ASME AG-1 - 2015: Code on Nuclear Air and Gas Treatment, 2015
- CONTENTS
- FOREWORD
- COMMITTEE ROSTER
- ORGANIZATION OF ASME AG-1
- SUMMARY OF CHANGES
- Division I General Requirements [Go to Page]
- SECTION AA COMMON ARTICLES [Go to Page]
- ARTICLE AA-1000 INTRODUCTION
- ARTICLE AA-2000 REFERENCED DOCUMENTS
- ARTICLE AA-3000 MATERIALS
- ARTICLE AA-4000 STRUCTURAL DESIGN
- ARTICLE AA-5000 INSPECTION AND TESTING
- ARTICLE AA-6000 FABRICATION, JOINING, WELDING, BRAZING,PROTECTIVE COATING, AND INSTALLATION
- ARTICLE AA-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE,AND HANDLING
- ARTICLE AA-8000 QUALITY ASSURANCE
- ARTICLE AA-9000 NAMEPLATES AND STAMPING
- ARTICLE AA-10000 REPAIR AND REPLACEMENT OF COMPONENTS
- Figures [Go to Page]
- FIG. AA-4355.3 SINE BEAT FREQUENCY AND AMPLITUDE
- FIG. AA-4355.4 SINE AMPLITUDE DECAY RATE
- FIG. AA-4356.4-1 RESPONSE SPECTRUM OF COMPOSITE EXCITATION
- FIG. AA-4356.4-2 OSCILLATIONS PER BEAT
- FIG. AA-6324.2 ACCEPTABLE AND UNACCEPTABLE WELD PROFILES
- FIG. AA-8130 HIERARCHY OF RESPONSIBILITY
- Tables [Go to Page]
- TABLE AA-3100 ALLOWABLE MATERIALS
- TABLE AA-4212 LOAD CONDITIONS
- TABLE AA-4231 DEFLECTION LIMITS
- TABLE AA-4321 PLATE- AND SHELL-TYPE COMPONENTS: PRIMARY STRESS ALLOWABLES
- TABLE AA-4323 LINEAR-TYPE SYSTEMS: PRIMARY STRESS ALLOWABLES
- TABLE AA-10530 LIFETIME REPAIR AND REPLACEMENT RECORDS
- TABLE AA-10540 NONPERMANENT REPAIR AND REPLACEMENT RECORDS
- NONMANDATORY APPENDIX AA-A DESIGN AND QUALIFICATION BY ANALYSIS
- NONMANDATORY APPENDIX AA-B SEISMIC QUALIFICATION BY TESTING
- NONMANDATORY APPENDIX AA-C QUALIFICATION BY A COMBINATION OFANALYSIS AND TESTING
- Division II Ventilation Air Cleaning and Ventilation Air Conditioning [Go to Page]
- SECTION BA FANS AND BLOWERS [Go to Page]
- ARTICLE BA-1000 INTRODUCTION
- ARTICLE BA-2000 REFERENCED DOCUMENTS
- ARTICLE BA-3000 MATERIALS
- ARTICLE BA-4000 DESIGN
- ARTICLE BA-5000 INSPECTION AND TESTING
- ARTICLE BA-6000 FABRICATION AND INSTALLATION OFCENTRIFUGAL AND AXIAL FANS
- ARTICLE BA-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE,AND HANDLING
- ARTICLE BA-8000 QUALITY ASSURANCE
- ARTICLE BA-9000 NAMEPLATES AND OPERATING ANDMAINTENANCE MANUALS
- TABLE [Go to Page]
- TABLE BA-4162MAXIMUM ALLOWABLE DISPLACEMENT
- NONMANDATORY APPENDIX BA-A FAN SYSTEM CONSIDERATIONS
- NONMANDATORY APPENDIX BA-B DIVISION OF RESPONSIBILITY
- SECTION DA DAMPERS AND LOUVERS [Go to Page]
- ARTICLE DA-1000 INTRODUCTION
- ARTICLE DA-2000 REFERENCED DOCUMENTS
- ARTICLE DA-3000 MATERIALS
- ARTICLE DA-4000 DESIGN
- ARTICLE DA-5000 INSPECTION AND TESTING
- ARTICLE DA-6000 FABRICATION, FINISHING, AND INSTALLATION
- ARTICLE DA-7000 PACKAGING, SHIPPING, AND STORAGE
- ARTICLE DA-8000 QUALITY ASSURANCE
- ARTICLE DA-9000 NAMEPLATES, STAMPINGS, AND MANUALS
- MANDATORY APPENDIX DA-I SEAT AND FRAME LEAKAGE
- MANDATORY APPENDIX DA-II DAMPER AND LOUVER CONFIGURATIONS
- NONMANDATORY APPENDIX DA-A DIVISION OF RESPONSIBILITY
- SECTION SA DUCTWORK [Go to Page]
- ARTICLE SA-1000 INTRODUCTION
- ARTICLE SA-2000 REFERENCED DOCUMENTS
- ARTICLE SA-3000 MATERIALS
- ARTICLE SA-4000 DESIGN
- ARTICLE SA-5000 INSPECTION AND TESTING
- ARTICLE SA-6000 FABRICATION AND INSTALLATION
- ARTICLE SA-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE,AND HANDLING
- ARTICLE SA-8000 QUALITY ASSURANCE
- ARTICLE SA-9000 NAMEPLATES AND STAMPING
- Figure [Go to Page]
- FIG. SA-1120 DUCTWORK AND DUCTWORK SUPPORT Ð INTERFACE BOUNDARY
- Tables [Go to Page]
- TABLE SA-6410-1 RECTANGULAR DUCTS: MAXIMUM ALLOWABLE TOLERANCES
- TABLE SA-6410-2 CIRCULAR DUCTS: MAXIMUM ALLOWABLE TOLERANCES
- TABLE SA-6410-3 FLATNESS OF SURFACE: MAXIMUM ALLOWABLE WAVINESS TOLERANCE
- NONMANDATORY APPENDIX SA-A DIVISION OF RESPONSIBILITY
- NONMANDATORY APPENDIX SA-B PROCEDURES TO DETERMINE ALLOWABLE LEAKAGE FOR DUCTWORK
- NONMANDATORY APPENDIX SA-C ADDITIONAL GUIDELINES FOR DUCT DESIGN AND CONSTRUCTION
- SECTION HA HOUSINGS [Go to Page]
- ARTICLE HA-1000 INTRODUCTION
- ARTICLE HA-2000 REFERENCED DOCUMENTS
- ARTICLE HA-3000 MATERIALS
- ARTICLE HA-4000 DESIGN
- ARTICLE HA-5000 INSPECTION AND TESTING
- ARTICLE HA-6000 FABRICATION
- ARTICLE HA-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE,AND HANDLING
- ARTICLE HA-8000 QUALITY ASSURANCE
- ARTICLE HA-9000 NAMEPLATES AND STAMPING
- Figures [Go to Page]
- FIG. HA-1120-1 HOUSING, AIR CLEANING UNIT: WALK-IN TYPE
- FIG. HA-1120-2 HOUSING, AIR CLEANING UNIT: SIDE-ACCESS TYPE
- FIG. HA-1120-3 HOUSING, AIR CONDITIONING UNIT: WALK-IN TYPE
- Table [Go to Page]
- TABLE HA-4212 LOAD COMBINATIONS
- NONMANDATORY APPENDIX HA-A DIVISION OF RESPONSIBILITY
- NONMANDATORY APPENDIX HA-B ADDITIONAL GUIDELINES FOR HOUSING DESIGN AND CONSTRUCTION
- NONMANDATORY APPENDIX HA-C MANIFOLD DESIGN GUIDELINES
- NONMANDATORY APPENDIX HA-D PERFORMANCE TEST FOR QUALIFICATION OFSAMPLING MANIFOLDS
- SECTION RA REFRIGERATION EQUIPMENT [Go to Page]
- ARTICLE RA-1000 INTRODUCTION
- ARTICLE RA-2000 REFERENCED DOCUMENTS
- ARTICLE RA-3000 MATERIALS
- ARTICLE RA-4000 DESIGN REQUIREMENTS
- ARTICLE RA-5000 INSPECTION, RATING, AND TESTING
- ARTICLE RA-6000 FABRICATION AND INSTALLATION
- ARTICLE RA-7000 PACKAGING, SHIPPING, STORAGE, AND HANDLING
- ARTICLE RA-8000 QUALITY ASSURANCE
- ARTICLE RA-9000 NAMEPLATES, STAMPING, AND RECORDS
- Forms [Go to Page]
- FORM RA-1 MANUFACTURER'S DATA REPORT FOR SECTION RA NON-ASME NUCLEAR VESSELS1 (CUSTOMARY)
- FORM RA-M1 MANUFACTURER'S DATA REPORT FOR SECTION RA NON-ASME NUCLEAR VESSELS1 (SI)
- FORM RA-2 CENTRIFUGAL COMPRESSOR TEST RECORD
- FORM RA-2a CENTRIFUGAL COMPRESSOR OIL PUMP PRESSURE TEST
- FORM RA-2b CENTRIFUGAL COMPRESSOR PRESSURE TEST RECORD
- FORM RA-3 RECIPROCATING SCROLL/SCREW COMPRESSOR TESTRECORD
- FORM RA-3a RECIPROCATING SCROLL/SCREW COMPRESSOR PRESSURETEST RECORD
- FORM RA-4 ELECTRICAL TEST RECORD Ð CONTROLS AND CONTROL PANELS
- FORM RA-5 PERFORMANCE TEST RECORD (CUSTOMARY)
- FORM RA-M5 PERFORMANCE TEST RECORD (SI)
- MANDATORY APPENDIX RA-I PERFORMANCE TESTING OF CHILLED WATER REFRIGERATION UNIT (CUSTOMARY)
- MANDATORY APPENDIX RA-MI PERFORMANCE TESTING OF CHILLED WATER REFRIGERATION UNIT (SI)
- MANDATORY APPENDIX RA-II MANDATORY LIST OF INSTRUMENTATION FUNCTIONS AND CONTROL FUNCTIONS
- NONMANDATORY APPENDIX RA-A DIVISION OF RESPONSIBILITY
- NONMANDATORY APPENDIX RA-B TYPICAL EXTERNAL INTERFACE DIAGRAMS
- SECTION CA CONDITIONING EQUIPMENT [Go to Page]
- ARTICLE CA-1000 INTRODUCTION
- ARTICLE CA-2000 REFERENCED DOCUMENTS
- ARTICLE CA-3000 MATERIALS
- ARTICLE CA-4000 DESIGN
- ARTICLE CA-5000 INSPECTION AND TESTING
- ARTICLE CA-6000 FABRICATION AND INSTALLATION
- ARTICLE CA-7000 PACKAGING, SHIPPING, STORAGE, AND HANDLING
- ARTICLE CA-8000 QUALITY ASSURANCE
- ARTICLE CA-9000 NAMEPLATES AND RECORDS
- Tables [Go to Page]
- TABLE CA-4122 MAXIMUM WATER VELOCITIES IN WATER COILS
- TABLE CA-8120-1 LIFETIME QUALITY ASSURANCE RECORDS
- TABLE CA-8120-2 NONPERMANENT QUALITY ASSURANCE RECORDS
- MANDATORY APPENDIX CA-I MANUFACTURER'S DATA REPORTS
- MANDATORY APPENDIX CA-II FACTORY TESTING OF EVAPORATIVE COOLERS AND AIR WASHERS
- NONMANDATORY APPENDIX CA-A DIVISION OF RESPONSIBILITY
- NONMANDATORY APPENDIX CA-B DESIGN RECOMMENDATIONS
- SECTION FA MOISTURE SEPARATORS [Go to Page]
- ARTICLE FA-1000 INTRODUCTION
- ARTICLE FA-2000 REFERENCED DOCUMENTS
- ARTICLE FA-3000 MATERIALS
- ARTICLE FA-4000 DESIGN
- ARTICLE FA-5000 INSPECTION AND TESTING
- ARTICLE FA-6000 FABRICATION
- ARTICLE FA-7000 PACKAGING, SHIPPING, AND STORAGE
- ARTICLE FA-8000 QUALITY ASSURANCE
- ARTICLE FA-9000 NAMEPLATES
- Figure [Go to Page]
- FIG. FA-4100-1 TYPICAL MOISTURE SEPARATION CONFIGURATION
- Table [Go to Page]
- TABLE FA-4200-1 MOISTURE SEPARATOR PERFORMANCE SPECIFICATIONS
- NONMANDATORY APPENDIX FA-A DIVISION OF RESPONSIBILITY
- SECTION FB MEDIUM EFFICIENCY FILTERS [Go to Page]
- ARTICLE FB-1000 INTRODUCTION
- ARTICLE FB-2000 REFERENCED DOCUMENTS
- ARTICLE FB-3000 MATERIALS
- ARTICLE FB-4000 DESIGN
- ARTICLE FB-5000 INSPECTION AND TESTING
- ARTICLE FB-6000 FABRICATION
- ARTICLE FB-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE, AND HANDLING
- ARTICLE FB-8000 QUALITY ASSURANCE
- ARTICLE FB-9000 LABELS AND MARKING
- NONMANDATORY APPENDIX FB-A DIVISION OF RESPONSIBILITY
- SECTION FC HEPA FILTERS [Go to Page]
- ARTICLE FC-1000 INTRODUCTION
- ARTICLE FC-2000 REFERENCED DOCUMENTS
- ARTICLE FC-3000 MATERIALS
- ARTICLE FC-4000 DESIGN
- ARTICLE FC-5000 INSPECTION AND TESTING
- ARTICLE FC-6000 FABRICATION
- ARTICLE FC-7000 PACKAGING, SHIPPING, AND STORAGE
- ARTICLE FC-8000 QUALITY ASSURANCE
- ARTICLE FC-9000 NAMEPLATES
- Figures [Go to Page]
- FIG. FC-4110-1 TYPE A, C, or D METAL-CASED, GASKET-SEALED FILTER
- FIG. FC-4110-2 TYPE A WOOD CASE SEPARATOR FILTER
- FIG. FC-4110-3 TYPE B MINIPLEAT FILTER
- FIG. FC-4110-4 TYPE C SEPARATORLESS FILTER
- FIG. FC-4110-5 TYPE D THREAD SEPARATOR FILTER
- FIG. FC-4142-1 GEL SEAL FILTER CORNER - ISOMETRIC
- Tables [Go to Page]
- TABLE FC-4110 NOMINAL SIZES AND RATINGS
- TABLE FC-5100-1 TEST GROUPS AND SEQUENCE
- TABLE FC-5120-1 ACCEPTABLE TEST
- TABLE FC-5140-1 TEST CONDITIONS AND REQUIREMENTS
- MANDATORY APPENDIX FC-I FILTER MEDIA: FIRE-RESISTANT, HIGH EFFICIENCY
- NONMANDATORY APPENDIX FC-A DIVISION OF RESPONSIBILITY
- SECTION FD TYPE II ADSORBER CELLS [Go to Page]
- ARTICLE FD-1000 INTRODUCTION
- ARTICLE FD-2000 REFERENCED DOCUMENTS
- ARTICLE FD-3000 MATERIALS
- ARTICLE FD-4000 DESIGN
- ARTICLE FD-5000 INSPECTION AND TESTING
- ARTICLE FD-6000 FABRICATION
- ARTICLE FD-7000 PACKAGING AND SHIPPING
- ARTICLE FD-8000 QUALITY ASSURANCE
- ARTICLE FD-9000 NAMEPLATES AND CERTIFICATION
- Figure [Go to Page]
- FIG. FD-4100 TYPE II ADSORBER CELL
- Tables [Go to Page]
- TABLE FD-5332 DETECTOR SENSITIVITY FOR LEAK TEST
- TABLE FD-6100 CELL DIMENSIONS AND TOLERANCES
- MANDATORY APPENDIX FD-I CALCULATION OF RESIDENCE TIME OF ADSORBER CELLS
- MANDATORY APPENDIX FD-II SAMPLE CANISTERS
- NONMANDATORY APPENDIX FD-A DIVISION OF RESPONSIBILITY
- SECTION FE TYPE III ADSORBERS [Go to Page]
- ARTICLE FE-1000 INTRODUCTION
- ARTICLE FE-2000 REFERENCED DOCUMENTS
- ARTICLE FE-3000 MATERIALS
- ARTICLE FE-4000 DESIGN
- ARTICLE FE-5000 INSPECTION AND TESTING
- ARTICLE FE-6000 FABRICATION AND INSTALLATION
- ARTICLE FE-7000 PACKAGING AND SHIPPING
- ARTICLE FE-8000 QUALITY ASSURANCE
- ARTICLE FE-9000 NAMEPLATES
- Figure [Go to Page]
- FIG. FE-4110 HORIZONTAL SECTION OF TYPE III ADSORBER BED
- MANDATORY APPENDIX FE-I RESIDENCE TIME CALCULATION
- MANDATORY APPENDIX FE-II SCREEN WAVINESS INSPECTION TEST
- MANDATORY APPENDIX FE-III ADSORBER FILLING QUALIFICATION TEST PROCEDURE
- MANDATORY APPENDIX FE-IV TYPE III ADSORBER QUALIFICATION TEST PROCEDURE
- MANDATORY APPENDIX FE-V SAMPLE CANISTERS
- NONMANDATORY APPENDIX FE-A VISUAL INSPECTION RECOMMENDATIONS FOR TYPE III ADSORBERS
- NONMANDATORY APPENDIX FE-B DIVISION OF RESPONSIBILITY
- SECTION FF ADSORBENT MEDIA [Go to Page]
- ARTICLE FF-1000 INTRODUCTION
- ARTICLE FF-2000 REFERENCED DOCUMENTS
- ARTICLE FF-3000 MATERIALS
- ARTICLE FF-4000 DESIGN
- ARTICLE FF-5000 INSPECTION AND TESTING
- ARTICLE FF-6000 FABRICATION
- ARTICLE FF-7000 PACKAGING AND SHIPPING
- ARTICLE FF-8000 QUALITY ASSURANCE
- ARTICLE FF-9000 NAMEPLATE AND CERTIFICATION
- NONMANDATORY APPENDIX FF-A DIVISION OF RESPONSIBILITY
- SECTION FG MOUNTING FRAMES FOR AIR-CLEANING EQUIPMENT [Go to Page]
- ARTICLE FG-1000 INTRODUCTION
- ARTICLE FG-2000 REFERENCED DOCUMENTS
- ARTICLE FG-3000 MATERIALS
- ARTICLE FG-4000 DESIGN
- ARTICLE FG-5000 INSPECTION AND TESTING
- ARTICLE FG-6000 FABRICATION
- ARTICLE FG-7000 PACKAGING AND SHIPPING
- ARTICLE FG-8000 QUALITY ASSURANCE
- ARTICLE FG-9000 NAMEPLATES
- Figures [Go to Page]
- FIG. FG-4110-1 TYPICAL FILTER MOUNTING FRAME
- FIG. FG-4120-1 TYPICAL TYPE II ADSORBER MOUNTING FRAME
- FIG. FG-4140-1 TYPICAL MOISTURE SEPARATOR MOUNTING FRAME
- NONMANDATORY APPENDIX FG-A DIVISION OF RESPONSIBILITY
- SECTION FH OTHER ADSORBERS [Go to Page]
- ARTICLE FH-1000 INTRODUCTION
- ARTICLE FH-2000 REFERENCED DOCUMENTS
- ARTICLE FH-3000 MATERIALS
- ARTICLE FH-4000 DESIGN
- ARTICLE FH-5000 INSPECTION AND TESTING
- ARTICLE FH-6000 FABRICATION
- ARTICLE FH-7000 PACKAGING AND SHIPPING
- ARTICLE FH-8000 QUALITY ASSURANCE
- ARTICLE FH-9000 NAMEPLATES AND CERTIFICATION
- Figures [Go to Page]
- FIG. FH-4000-1 TYPE IV "V" ADSORBERS MODEL (FLUID SEAL VERSION)
- FIG. FH-4000-1A TYPE IV "V" BED ADSORBERS MODEL (GASKETED VERSION)
- FIG. FH-4000-2 TYPE IV "V" ADSORBERS MODEL, EXPLODED VIEW
- FIG. FH-4000-3 TYPE IV "U" BED ADSORBERS MODEL (GASKETED VERSION)
- Table [Go to Page]
- TABLE FH-6100 DIMENSIONAL REQUIREMENTS
- NONMANDATORY APPENDIX FH-A DIVISION OF RESPONSIBILITY
- SECTION FI METAL MEDIA FILTERS
- SECTION FJ LOW EFFICIENCY FILTERS [Go to Page]
- ARTICLE FJ-1000 INTRODUCTION
- ARTICLE FJ-2000 REFERENCED DOCUMENTS
- ARTICLE FJ-3000 MATERIALS
- ARTICLE FJ-4000 DESIGN
- ARTICLE FJ-5000 INSPECTION AND TESTING
- ARTICLE FJ-6000 FABRICATION
- ARTICLE FJ-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE, AND HANDLING
- ARTICLE FJ-8000 QUALITY ASSURANCE
- ARTICLE FJ-9000 LABELS AND MARKINGS
- NONMANDATORY APPENDIX FJ-A DIVISION OF RESPONSIBILITY
- SECTION FK SPECIAL HEPA FILTERS [Go to Page]
- ARTICLE FK-1000 INTRODUCTION
- ARTICLE FK-2000 REFERENCED DOCUMENTS
- ARTICLE FK-3000 MATERIALS
- ARTICLE FK-4000 DESIGN
- ARTICLE FK-5000 QUALIFICATION, INSPECTION, AND PRODUCTIONTESTING
- ARTICLE FK-6000 FABRICATION
- ARTICLE FK-7000 PACKAGING, SHIPPING, AND STORAGE
- ARTICLE FK-8000 QUALITY ASSURANCE
- ARTICLE FK-9000 NAMEPLATES
- Figures [Go to Page]
- FIG. FK-4100-1 TYPE 1 RADIAL FLOW HEPA FILTER (INTERNAL GASKET), MIDSECTION VIEW
- FIG. FK-4100-2 TYPE 1 RADIAL FLOW HEPA FILTER (INTERNAL GELATINOUS SEAL), MIDSECTION VIEW
- FIG. FK-4100-3 TYPE 1 RADIAL FLOW HEPA FILTER (EXTERNAL GASKET), MIDSECTION VIEW
- FIG. FK-4100-4 TYPE 1 RADIAL FLOW HEPA FILTER (EXTERNAL GELATINOUS SEAL), MIDSECTION VIEW
- FIG. FK-4100-5 TYPE 2 AXIAL FLOW CIRCULAR HEPA FILTER
- FIG. FK-4100-6 TYPE 2 AXIAL FLOW CIRCULAR HEPA FILTER
- Tables [Go to Page]
- TABLE FK-4000-1 TYPE 1 RADIAL FLOW HEPA FILTER - NOMINAL RATING
- TABLE FK-4000-2 TYPE 2 AXIAL FLOW CIRCULAR HEPA FILTER - NOMINAL RATING
- TABLE FK-4000-3 PERFORMANCE REQUIREMENTS
- TABLE FK-5000-1 TEST GROUPS AND SEQUENCE - TYPE 1 RADIAL FLOW HEPA FILTERS
- TABLE FK-5000-2 TEST GROUPS AND SEQUENCE - TYPE 2 AXIAL FLOW CIRCULAR HEPA FILTERS
- TABLE FK-5000-3 TEST GROUPS AND SEQUENCE - TYPE 4 AXIAL FLOW RECTANGULAR HEPA FILTERS
- TABLE FK-5000-4 TEST CONDITIONS AND REQUIREMENTS
- NONMANDATORY APPENDIX FK-ADETERMINATION OF HEPA FILTER SERVICE LIFE
- NONMANDATORY APPENDIX FK-BDIVISION OF RESPONSIBILITY
- SECTION FL DEEP BED SAND FILTERS [Go to Page]
- ARTICLE FL-1000 INTRODUCTION
- ARTICLE FL-2000 REFERENCED DOCUMENTS
- ARTICLE FL-3000 MATERIALS
- ARTICLE FL-4000 DESIGN
- ARTICLE FL-5000 INSPECTION AND TESTING
- ARTICLE FL-6000 FABRICATION/FIELD CONSTRUCTION
- ARTICLE FL-7000 PACKAGING, SHIPPING, RECEIVING,STORAGE, AND HANDLING
- ARTICLE FL-8000 QUALITY ASSURANCE
- ARTICLE FL-9000 LABELS AND MARKINGS
- Figures [Go to Page]
- FIG. FL-4120-1 TYPICAL DBS FILTER CROSS SECTION, DOE-HDBK-1169-2003
- MANDATORY APPENDIX FL-I AIR-AEROSOL MIXING TEST PROCEDURAL GUIDELINES
- MANDATORY APPENDIX FL-II DEEP BED SAND FILTER IN-PLACELEAK TEST PROCEDURAL GUIDELINES
- NONMANDATORY APPENDIX FL-A DIVISION OF RESPONSIBILITY
- NONMANDATORY APPENDIX FL-B GUIDELINES FOR DEEP BED SAND FILTERS
- SECTION FM HIGH-STRENGTH HEPA FILTERS
- SECTION IA INSTRUMENTATION AND CONTROLS [Go to Page]
- ARTICLE IA-1000 INTRODUCTION
- ARTICLE IA-2000 REFERENCED DOCUMENTS
- ARTICLE IA-3000 MATERIALS
- ARTICLE IA-4000 DESIGN REQUIREMENTS
- ARTICLE IA-5000 INSPECTION AND TESTING
- ARTICLE IA-6000 PANEL FABRICATION AND ASSEMBLY
- ARTICLE IA-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE, AND HANDLING
- ARTICLE IA-8000 QUALITY ASSURANCE
- ARTICLE IA-9000 NAMEPLATES
- Table [Go to Page]
- TABLE IA-3100 ALLOWABLE MATERIALS
- NONMANDATORY APPENDIX IA-A DIVISION OF RESPONSIBILITY
- NONMANDATORY APPENDIX IA-B SAMPLE CHECKLIST FOR VISUAL EXAMINATION OF CONTROL PANELS/ENCLOSURES, INSTRUMENTS, AND CONTROL DEVICES
- NONMANDATORY APPENDIX IA-C INSTRUMENTATION FOR NUCLEAR AIR AND GAS TREATMENT SYSTEMS
- Division III Process Gas Treatment [Go to Page]
- SECTION GA PRESSURE VESSELS, PIPING, HEAT EXCHANGERS, AND VALVES
- SECTION GB NOBLE GAS HOLD-UP EQUIPMENT
- SECTION GC GAS COMPRESSORS AND EXHAUSTERS [Go to Page]
- ARTICLE GC-1000 INTRODUCTION
- ARTICLE GC-2000 REFERENCED DOCUMENTS
- ARTICLE GC-3000 MATERIALS
- ARTICLE GC-4000 DESIGN
- ARTICLE GC-5000 INSPECTION AND TESTING
- ARTICLE GC-6000 FABRICATION AND INSTALLATION
- ARTICLE GC-7000 PACKAGING, SHIPPING, RECEIVING, AND STORAGE
- ARTICLE GC-8000 QUALITY ASSURANCE
- ARTICLE GC-9000 NAMEPLATES AND OPERATING AND MAINTENANCE MANUALS
- MANDATORY APPENDIX GC-I SHAFT LEAKAGE
- MANDATORY APPENDIX GC-II SYSTEM CONSIDERATIONS
- NONMANDATORY APPENDIX GC-A DIVISION OF RESPONSIBILITY
- SECTION GD OTHER RADIONUCLIDE EQUIPMENT
- SECTION GE HYDROGEN RECOMBINERS
- SECTION GF GAS SAMPLING
- SECTION GG SCRUBBERS
- SECTION GH CYCLONES
- SECTION GI MEMBRANES
- SECTION GJ FILTERS
- SECTION GK MIST ELIMINATORS
- SECTION GL ELASTOMERIC PRECIPITATORS
- SECTION GM ADSORBENT MEDIA
- Division IV Testing Procedures [Go to Page]
- SECTION TA FIELD TESTING OF AIR TREATMENT SYSTEMS [Go to Page]
- ARTICLE TA-1000 INTRODUCTION
- ARTICLE TA-2000 REFERENCED DOCUMENTS
- ARTICLE TA-3000 GENERAL INSPECTION AND TEST REQUIREMENTS
- ARTICLE TA-4000 FIELD ACCEPTANCE TESTS
- ARTICLE TA-5000 CORRECTIVE ACTION REQUIREMENTS
- ARTICLE TA-6000 QUALITY ASSURANCE
- Tables [Go to Page]
- TABLE TA-3200 INSTRUMENT ACCURACY REQUIREMENTS
- TABLE TA-4110 FAN ACCEPTANCE TESTS
- TABLE TA-4210 DAMPER ACCEPTANCE TESTS
- TABLE TA-4310 DUCT, HOUSING, AND FRAME ACCEPTANCE TESTS
- TABLE TA-4410 REFRIGERATION EQUIPMENT ACCEPTANCE TESTS
- TABLE TA-4510 CONDITIONING EQUIPMENT ACCEPTANCE TESTS
- TABLE TA-4610 MOISTURE SEPARATOR, PREFILTER, AND HEPA FILTER ACCEPTANCE TESTS
- TABLE TA-4710 TYPES II, III, AND IV ADSORBER BANK ACCEPTANCE TESTS
- MANDATORY APPENDIX TA-I VISUAL INSPECTION CHECKLIST
- MANDATORY APPENDIX TA-II STRUCTURAL CAPABILITYTEST PROCEDURAL GUIDELINES
- MANDATORY APPENDIX TA-III DUCT AND HOUSING LEAK TEST PROCEDURAL GUIDELINES
- MANDATORY APPENDIX TA-IV AIRFLOW DISTRIBUTION TEST PROCEDURAL GUIDELINES
- MANDATORY APPENDIX TA-V AIR-AEROSOL MIXING TEST PROCEDURAL GUIDELINES
- MANDATORY APPENDIX TA-VI HEPA FILTER BANK IN-PLACE LEAK TEST PROCEDURAL GUIDELINES
- MANDATORY APPENDIX TA-VII ADSORBER BANK IN-PLACE LEAK TEST PROCEDURAL GUIDELINES
- MANDATORY APPENDIX TA-VIII REFRIGERANT PIPING AND COIL SYSTEM LEAK TEST PROCEDURAL GUIDELINES
- NONMANDATORY APPENDIX TA-A MOUNTING FRAME PRESSURE LEAK TEST PROCEDURAL GUIDELINES
- NONMANDATORY APPENDIX TA-B CORRECTIVE ACTION GUIDANCE
- NONMANDATORY APPENDIX TA-C CHALLENGE GAS AND AEROSOL SUBSTITUTE SELECTION CRITERIA
- SECTION TB FIELD TESTING OF GAS-PROCESSING SYSTEMS
- MANDATORY APPENDIX I PREPARATION OF TECHNICAL INQUIRIES TO THE COMMITTEE ON NUCLEAR AIR AND GAS TREATMENT
- NONMANDATORY APPENDIX A FORMAT GUIDE FOR TECHNICAL INQUIRIES
- ASME AG-1 INTERPRETATIONS [Go to Page]