EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-E1731 2011ASTM E1731 - 11Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom GlovesActive Standard ASTM E1731 | Developed by Subcommittee: E21.05 Book of Standards Volume: 15.03 ASTM E1731Significance and Use The NVR obtained by this test method is that amount which is available for release by the gloves onto handled surfaces. Evaporation of solvent at the stated temperature is to quantify the NVR that can be expected to exist at room temperature, since the slight difference between room temperature and the test temperature is not likely to result in significant variances. This method may be more aggressive than necessary to determine the suitability of cleanroom gloves that are restricted to dry operations only. Various other methods exist for determining NVR, for example Practice G120 and IES-RP-CC005. This test is not intended to replace test methods used for other purposes. 1. Scope 1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested. 1.2 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards D1193 Specification for Reagent Water E2217 Practice for Design and Construction of Aerospace Cleanrooms and Contamination Controlled Areas F50 Practice for Continuous Sizing and Counting of Airborne Particles in Dust-Controlled Areas and Clean Rooms Using Instruments Capable of Detecting Single Sub-Micrometre and Larger Particles G120 Practice for Determination of Soluble Residual Contamination by Soxhlet Extraction Federal Standards FedStd209E Airborne Particulate Cleanliness Classes in Cleanrooms and Clean Zones Fed-Std-209E has been replaced by ISO 14644-1 and -2, but may continue to be used by mutual agreement.Other Documents ISO14644-2 Cleanrooms and Associated Controlled Environments, Specifications for testing and monitoring to prove continued compliance with ISO 14644-1Keywords cleanroom gloves; gloves; non-volatile residue; NVR; Cleanrooms (materials/applications); Gloves; Gravimetric determination; Nonvolatile residue (NVR); Residue ; ICS Code ICS Number Code 49.025.99 (Other materials); 71.040.50 (Physicochemical methods of analysis) DOI: 10.1520/E1731-11 ASTM International is a member of CrossRef. ASTM E1731The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |