ASTM E2190-08
Historical Standard: ASTM E2190-08 Standard Specification for Insulating Glass Unit Performance and Evaluation
SUPERSEDED (see Active link, below)
ASTM E2190
1. Scope
1.1 This specification covers preassembled permanently sealed insulating glass units with one or two airspaces and preassembled insulating glass units with capillary tubes intentionally left open.
1.2 This specification is applicable only to sealed insulating glass units that are constructed with glass.
1.3 The qualification of test specimens is based on frost/dew point and on the absence of fog after the specified test durations.
1.4 Qualification under this specification is intended to provide a basis for evaluating the durability of sealed insulating glass units.
1.5 This specification is not applicable to sealed insulating glass units containing a spandrel glass coating due to test method limitations.
1.6 This specification does not cover other physical requirements such as appearance, thermophysical properties, heat and light transmission, and glass displacement.
Note 1Sealed insulating glass units qualified according to this specification are not necessarily suitable for structurally glazed applications. Factors such as sealant longevity when exposed to long term ultraviolet light and the structural properties of the sealant must be reviewed for these applications. For more information on the requirements for structural sealant glazing applications, refer to Specification C 1369 , Guide C 1249 , and Test Method C 1265 .
1.7 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only and are not considered standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C162 Terminology of Glass and Glass Products
C717 Terminology of Building Seals and Sealants
C1036 Specification for Flat Glass
C1249 Guide for Secondary Seal for Sealed Insulating Glass Units for Structural Sealant Glazing Applications
C1265 Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications
C1369 Specification for Secondary Edge Sealants for Structurally Glazed Insulating Glass Units
E546 Test Method for Frost/Dew Point of Sealed Insulating Glass Units
E631 Terminology of Building Constructions
E2188 Test Method for Insulating Glass Unit Performance
E2189 Test Method for Testing Resistance to Fogging in Insulating Glass Units
E2269 Test Method for Determining Argon Concentration in Sealed Insulating Glass Units using Gas Chromatography
E2649 Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy
Keywords
gas concentration; insulating glass units; seal durability; sealed insulating glass units; unit performance and evaluation; Building materials/applications--specifications; Insulating glass (IG); Performance--building materials/applications (specifications); Preassemble peermanently-sealed IGO; Sealed insulating glass units--specifications;
ICS Code
ICS Number Code 81.040.20 (Glass in building)
DOI: 10.1520/E2190-08