Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Filters:
EDITION
to
PUBLISHER
(1)
(366)
(651)
(599)
(57)
(290)
(1055)
(738)
(2283)
(117)
(99009)
(58)
(650)
(137)
(42)
(29)
(20)
(102918)
(18)
(1)
(397)
(328)
(10763)
(7368)
(266)
(21)
(24376)
(1010)
(7)
(1737)
(26)
(19)
(28)
(4)
 
(6)
(7)
(128)
(1)
(4)
(58)
(5)
(7)
(1)
(1)
(2)
(28)
(27)
(36)
(13)
(71)
(24)
(27)
(7)
(8)
(20)
(1)
(3)
(50)
(7)
(34)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS EN ISO 80601-2-90:2026 - TC Tracked Changes. Medical electrical equipment - Particular requirements for basic safety and essential performance of respiratory high-flow therapy equipment
    Edition: 2026
    $819.89
    / user per year

Description of BS EN ISO 80601-2-90:2026 - TC 2026

This document applies to the basic safety and essential performance of respiratory high-flow therapy equipment, as defined in ?2 01.3.262, hereafter also referred to as ME equipment or ME system, in combination with its accessories: intended for use with patients who can breathe spontaneously; and intended for patients who would benefit from improved alveolar gas exchange; and who would benefit from receiving high-flow humidified respiratory gases, which can include a patient whose upper airway is bypassed. EXAMPLE 1 Patients with Type 1 Respiratory Failure who exhibit a reduction in arterial blood oxygenation. EXAMPLE 2 Patients who would benefit from reduced work of breathing, as needed in Type 2 Respiratory Failure, where arterial carbon dioxide is high. EXAMPLE 3 Patients requiring humidification to improve mucociliary clearance. Respiratory high-flow therapy equipment is utilized in both professional healthcare facilities and the home healthcare environment. This standard specifically addresses respiratory high-flow therapy equipment for acute or infant care, predominantly found in hospitals. A separate document for long term high-flow therapy in the home healthcare environment is expected to be forthcoming. Respiratory high-flow therapy equipment can be: fully integrated ME equipment; or a combination of separate items forming a ME system. This document also applies to other types of respiratory equipment when that equipment includes a respiratory high-flow therapy mode. NOTE 2  This document and ISO 80601-2-12 are applicable to a critical care ventilator with a high-flow therapy mode. NOTE 3  This document and ISO 80601-2-72 are applicable to ventilator for ventilator-dependent patients in the home healthcare environment with a high-flow therapy mode. NOTE 4  This document and ISO 80601-2-13 are applicable to an anaesthetic workstation with a high-flow therapy mode. Respiratory high-flow therapy equipment can be transit-operable. This document is also applicable to those accessories intended by their manufacturer to be connected to the respiratory high-flow therapy equipment, where the characteristics of those accessories can affect the basic safety or essential performance of the respiratory high-flow therapy equipment. EXAMPLE 4         Breathing sets, connectors, humidifier, breathing system filter, external electrical power source, distributed alarm system, high-flow nasal cannula, tracheal tube, tracheostomy tube, face mask and supra-laryngeal airway. NOTE 5        Accessories are assessed with the relevant clauses of this document when configured as part of respiratory high-flow therapy equipment. If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in the general standard, 7.2.13 and 8.4.1. NOTE 6        Additional information can be found in the general standard, 4.2. This document does not specify the requirements for: ventilators or accessories for ventilator-dependent patients intended for critical care applications, which are given in ISO 80601?2?12; ventilators or accessories intended for anaesthet



About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

GROUPS